Ubiquiti Pro XG 48 USW-Pro-XG-48 Dubai

Ubiquiti Pro XG 48 USW-Pro-XG-48 for High-Capacity Networks

The Ubiquiti Pro XG 48 USW-Pro-XG-48 is a professional 1U Layer 3 managed switch designed for organisations that need dense multi-gigabit access and high-capacity uplinks without PoE output. Its port layout combines 32 RJ45 interfaces supporting up to 10 GbE, 16 RJ45 interfaces supporting up to 2.5 GbE, and four SFP28 interfaces supporting up to 25G. This makes it relevant for server rooms, creative studios, data-intensive offices, virtualisation environments and UniFi deployments where many workstations, storage systems or downstream switches require faster-than-gigabit connectivity. Buyers should confirm whether the non-PoE design matches the project, which copper speeds each endpoint supports, and whether SFP28 optics or direct-attach cables are needed. Rack depth, cooling, UniFi Network version and redundant-power planning should also be reviewed before ordering. FourTeck can help Dubai and UAE customers assess port requirements, uplink design, compatible transceivers, rack installation scope and configuration needs. Availability, regional version and delivery timing may vary, so contact FourTeck with the required quantity, deployment location and target schedule to request a suitable quotation.

SKU: UBIQUITI-USW-PRO-XG-48-DUBAI Category:

High-density multi-gigabit switching

Ubiquiti Pro XG 48 USW-Pro-XG-48 in Dubai, UAE

The USW-Pro-XG-48 is a professional 1U Layer 3 UniFi switch created for networks that need many 10 GbE copper connections, multi-gigabit access ports and 25G fibre or direct-attach uplinks in a single rack unit. It is intended for performance-focused environments where switching density, traffic capacity and centralised UniFi management matter more than PoE delivery.

Before requesting a quote

  • Confirm that endpoints need 2.5G, 5G or 10G copper connectivity.
  • Confirm that PoE is not required from this switch.
  • Define 25G uplink media, distance and connector type.
  • Check rack depth, airflow and redundant-power plans.
  • Share quantity, destination and installation scope with FourTeck.
32 × 10 GbE RJ45High-density copper access
16 × 2.5 GbE RJ45Multi-gigabit edge links
4 × 25G SFP28High-capacity uplinks
1U Layer 3Rack-efficient managed switching

Direct answer for business buyers

The Ubiquiti USW-Pro-XG-48 is a non-PoE, high-capacity UniFi switch for organisations that need a large number of 10G and 2.5G copper ports together with 25G uplinks. It is mainly used to connect servers, network storage, high-performance workstations, production systems and downstream switching infrastructure. It should be considered by IT teams building or upgrading a UniFi-managed network where ordinary one-gigabit switching has become a bottleneck. Before proceeding, confirm endpoint speeds, cable category and distance, SFP28 transceiver or DAC requirements, rack depth, cooling, redundant-power expectations and whether a PoE model is actually needed.

What it does

The switch aggregates and forwards traffic between many high-speed wired devices while presenting those connections through the UniFi Network management platform. Its mix of copper and SFP28 interfaces allows a designer to combine 2.5G client or appliance links, 10G server and workstation links, and 25G uplinks toward aggregation or core infrastructure. Layer 2 and Layer 3 functions support segmentation, routing between local networks, access control and traffic-management tasks when configured within the supported UniFi environment.

Who it suits

This model is suited to businesses with a real need for dense multi-gigabit wired access: media production teams handling large files, engineering offices using central storage, virtualisation clusters, backup networks, research environments, high-performance labs, multi-tenant technology facilities and growing enterprise offices. It is less suitable when most endpoints are only 1G, when PoE must power access points or cameras, or when the required uplink architecture is based exclusively on lower-speed SFP+ connections.

Business challenges this switch can help address

Congested server access

When multiple users, virtual hosts or storage systems share one-gigabit links, large transfers and backup windows can become operational bottlenecks. The 10G port density allows more systems to receive dedicated high-speed copper links, provided the endpoint hardware and cabling support the selected speed.

Limited rack space

Combining 48 RJ45 ports and four 25G SFP28 interfaces in one rack unit can reduce the number of separate access and uplink devices required in some designs. The actual saving depends on port distribution, redundancy and whether PoE switching must remain separate.

Fragmented management

Organisations already using UniFi gateways, switches and access points may prefer to manage port settings, VLANs, alerts and topology from one application. Management convenience still depends on correct controller hosting, software version and operational processes.

Insufficient uplink headroom

Four 25G SFP28 ports give architects options for higher-capacity uplinks, link aggregation and connections to suitable aggregation switches or servers. Optics, fibre type, DAC length, port compatibility and topology must be confirmed before purchase.

Core capability band

Dense 10G copperThirty-two RJ45 ports negotiate from 10G down to lower supported Ethernet rates.
Multi-gigabit accessSixteen 2.5G RJ45 ports suit compatible devices that exceed one-gigabit needs.
25G uplink optionsFour SFP28 interfaces support 25G, 10G and 1G modes with suitable media.
UniFi Layer 3Local routing, DHCP and network segmentation features are available through supported UniFi software.

Product-fit matrix

RequirementSuitable whenConfirm before ordering
10G endpoint densityMany servers, NAS systems or workstations require dedicated 10GBase-T links.NIC speed, cable category, channel length and heat considerations.
2.5G accessA group of appliances or endpoints needs more than 1G but not full 10G.Port count, endpoint negotiation and whether PoE is required.
High-capacity uplinksThe design includes 25G-capable aggregation, storage or server interfaces.SFP28 module type, fibre standard, DAC length and peer compatibility.
UniFi operationsThe organisation prefers centralised UniFi monitoring and configuration.UniFi Network 9.0.114 or later and controller hosting approach.
Powered endpointsA separate PoE switch or injectors already serve powered devices.The USW-Pro-XG-48 itself does not provide PoE output.

Verified technical information

BrandUbiquiti
Product nameUniFi Pro XG 48
ModelUSW-Pro-XG-48
Product typeProfessional Layer 3 managed Ethernet switch
Form factor1U rack mount
2.5 GbE RJ45 ports16 ports supporting 2.5G/1G/100M/10M
10 GbE RJ45 ports32 ports supporting 10G/5G/2.5G/1G/100M/10M
SFP28 ports4 ports supporting 25G/10G/1G
PoE outputNo PoE output on this model
Switching capacity920 Gbps
Non-blocking throughput460 Gbps
Forwarding rate684 Mpps
Supported VLANsUp to 1,000
MAC address table32,000
IPv4 static routes512
Packet buffer8 MB
Layer 3 functionsDHCP server for local networks, DHCP relay, inter-VLAN routing and static routing
Layer 2 functionsIncludes LACP, STP/RSTP, IGMP snooping, 802.1X control, ACLs, DHCP snooping, isolation, port mirroring, jumbo frames, voice VLAN and loop protection
Maximum power consumption250W
Power input100–240V AC, 50/60 Hz, plus USP RPS DC input
Internal power supply300W AC/DC
Dimensions442 × 480 × 44 mm
Weight7.5 kg without brackets; 7.6 kg with brackets
EnclosureSGCC steel
Display1.3-inch touchscreen LCM
Operating temperature-5 to 40°C
Operating humidity10 to 90% non-condensing
Management requirementUniFi Network version 9.0.114 or later
AvailabilityContact FourTeck to confirm current UAE version, quantity and lead time

Important compatibility and dependency notice

The USW-Pro-XG-48 is the non-PoE model. It should not be confused with the USW-Pro-XG-48-PoE, which has a different power architecture and purchasing purpose. Confirm the exact model code on every quotation and purchase order. For 10G copper links, performance depends on endpoint NIC capability, cable category, cable quality, termination and link distance. For SFP28 connections, the transceiver, direct-attach cable or active optical cable must be compatible with both ends of the link.

Layer 3 and network-control features also depend on the deployed UniFi Network software version and configuration. Redundant power requires a suitable UniFi RPS design and cabling. Any optics, DACs, patch leads, rack accessories, installation work, controller hosting or configuration services should be itemised separately unless the quotation explicitly states they are included.

A practical purchase and deployment journey

1

Map connected devices

List servers, storage, workstations, security appliances and downstream switches. Record current and target interface speeds so that the 2.5G and 10G ports are allocated deliberately.

2

Design the uplinks

Decide whether one, two or more 25G links are needed and whether they will connect to aggregation, storage or compute infrastructure. Confirm optics, fibre and redundancy.

3

Review rack and power

Check rack depth, airflow, circuit capacity, UPS sizing and RPS expectations. A high-speed switch should be planned as part of the complete rack power and cooling budget.

4

Build the configuration

Prepare VLANs, trunks, link aggregation, access controls, routing and port profiles. Migration should be staged to avoid accidental loops, address conflicts or service disruption.

5

Test and document

Validate negotiated speeds, uplink resilience, VLAN reachability, monitoring and application performance. Record port assignments, cable paths, optics and rollback steps.

Dense 10G access without unnecessary port conversion

A common challenge in performance-oriented offices is that high-speed devices use 10GBase-T while the aggregation layer is largely optical. Designers then add media converters, smaller access switches or mixed modules simply to reach the required copper density. The USW-Pro-XG-48 places 32 multi-rate 10G RJ45 interfaces in one device, allowing compatible servers, NAS systems, editing workstations and specialist appliances to connect directly. Each of these ports can also negotiate at 5G, 2.5G, 1G and lower supported rates, which can be useful during phased upgrades.

That flexibility should not be mistaken for an automatic performance improvement. A 10G port only delivers value when the device, cabling and application can use it. Copper 10G may place greater demands on cable quality and thermal planning than ordinary gigabit networking. Buyers should verify existing structured cabling rather than assume every installed run will support the desired rate. Where distances, interference or pathway conditions are uncertain, testing representative links before a full migration is sensible. FourTeck can help translate the device schedule and cable environment into a port and media plan for quotation.

25G uplinks for a balanced switching architecture

High access-port density needs an uplink design that prevents traffic from converging onto a single undersized path. The four SFP28 ports can operate at 25G, 10G or 1G with suitable media, giving architects several ways to connect the switch to an aggregation layer, a storage fabric or selected compute systems. Two or more ports may be considered for link aggregation where the peer platform, design and failure model support it. Other ports may be reserved for independent storage or inter-switch connections.

The choice between direct-attach copper, active optical cable and modular fibre optics depends on distance, rack layout, cable management, electrical isolation and the ports available on the peer device. A DAC may be efficient inside or between nearby racks, while optical links may be more suitable across longer pathways. Buyers should confirm module speed, fibre mode, connector type, wavelength and compatibility on both ends. The quotation should list these accessories explicitly because they are not interchangeable and may not be included with the switch.

Operational control through UniFi Network

For organisations already invested in UniFi, the management experience can be as important as raw port count. UniFi Network provides a central interface for adoption, port configuration, network segmentation, topology visibility, firmware management and event review. The switch supports practical controls such as 802.1X, DHCP snooping, ACLs, port isolation, link aggregation, spanning tree, IGMP functions, voice VLAN and port mirroring. These features can support cleaner segmentation and troubleshooting when they are designed and maintained correctly.

Central management does not remove the need for governance. Teams should define who can change configuration, how updates are tested, how backups are retained and how emergency access is handled. UniFi Network version 9.0.114 or later is specified for this model, so controller compatibility should be checked before delivery. Where the switch is part of a migration from another vendor, VLAN IDs, native VLAN behaviour, link aggregation settings, spanning-tree priorities and monitoring expectations should be mapped carefully rather than copied without validation.

Ideal environments and practical use cases

Media and post-production

Editors and render systems frequently exchange large project files with shared storage. Dedicated 10G access can reduce transfer delays when the storage, clients and application workflows are appropriately sized.

Virtualisation clusters

Compute hosts may use multiple high-speed links for management, virtual machine traffic, migration and storage. Port allocation and redundancy should be planned with the hypervisor and server NIC design.

Central backup networks

Backup traffic can consume substantial bandwidth during limited windows. A dedicated multi-gigabit switching layer may help, but backup server, repository and disk performance must also support the target throughput.

Engineering and design offices

CAD, BIM, simulation and geospatial teams may work with large central datasets. The switch can provide dense fast access where workstation NICs and storage architecture are aligned.

Technology labs

Testing environments often need flexible combinations of 1G, 2.5G, 5G, 10G and 25G. Multi-rate ports help accommodate varied equipment, though lab segmentation and change control remain important.

UniFi campus distribution

The switch may serve as a high-speed distribution point for compatible downstream systems. Topology, failure domains, uplink oversubscription and the absence of PoE should be evaluated.

Integration and operational considerations

A high-speed switch should be selected as part of an end-to-end network rather than as an isolated component. Check every path from endpoint to application. A workstation connected at 10G may still experience slow access if the storage system has limited disk throughput, the server uses a one-gigabit interface, or the uplink is congested. Similarly, a 25G uplink does not guarantee application performance when routing, firewall inspection, server processing or WAN capacity is lower.

Cabling deserves particular attention. Existing Cat6, Cat6A or other structured cabling should be assessed against distance, installation quality and environmental conditions. Patch panels and patch leads are part of the channel and can affect link negotiation. For SFP28, maintain a documented optics and cable matrix so replacement parts match the deployed media.

The switch supports DC power backup through a compatible UniFi RPS connection, but true service resilience requires more than a second power source. Designers should consider upstream redundancy, link paths, aggregation behaviour, controller availability and the consequences of a single-switch failure. Where uninterrupted access is critical, two-switch architectures and endpoint bonding may be more appropriate than relying on one high-density device.

Operational teams should also plan firmware maintenance, configuration backups, monitoring thresholds and access rights. Port labels in software should match rack and cable documentation. A clear rollback plan is especially valuable during migrations involving VLAN changes, link aggregation or routing because a small configuration mismatch can affect many connected systems at once.

Questions to resolve before ordering

How many devices genuinely need 10G?

Separate current requirements from future estimates and include spare capacity without overbuilding the entire access layer.

Do any endpoints require PoE?

This model does not power access points, phones or cameras. A PoE switch or injectors must be planned separately.

What uplink topology is required?

Define peer devices, port speeds, link count, aggregation method, redundancy and media before choosing optics.

Can the rack support the chassis?

Review the 480 mm chassis depth, rack-post spacing, cable bend radius, ventilation and nearby equipment.

Is the UniFi controller ready?

Confirm controller hosting, backup, administrative access and UniFi Network version 9.0.114 or later.

What services belong in the quotation?

State whether installation, rack work, cabling, configuration, migration, testing and documentation are required.

Procurement checklist

✓ Exact model: USW-Pro-XG-48, not the PoE variant

✓ Required quantity and delivery destination

✓ Count of 2.5G, 5G and 10G endpoints

✓ Existing NIC and structured-cabling compatibility

✓ Number and purpose of 25G uplinks

✓ Required SFP28 optics, DACs or optical cables

✓ Rack depth, mounting and cable-management plan

✓ UPS circuit and optional RPS requirement

✓ UniFi Network controller version and hosting

✓ VLAN, routing and link-aggregation design

✓ Installation and migration responsibilities

✓ Warranty, regional version and lead-time confirmation

How FourTeck can assist

FourTeck can help turn a general request for a 48-port high-speed switch into a more accurate bill of materials. The review can cover endpoint counts, port-speed distribution, 25G uplink requirements, optics or DAC choices, rack constraints and the need for separate PoE switching. This helps reduce the risk of ordering the PoE variant by mistake, omitting required transceivers or discovering that existing cabling cannot support the planned links.

For deployment projects, customers can discuss rack installation, controller adoption, port profiles, VLANs, link aggregation, routing, firmware preparation, migration staging and test documentation. The final scope depends on the existing network, access permissions, cable readiness and the amount of change required. Services should be clearly listed in the quotation rather than assumed to be included with the hardware.

Businesses comparing this model with another UniFi switch can also request selection guidance. A lower-cost model may be more suitable when most links are 1G or 2.5G, while the PoE version may be necessary when the switch must power connected devices. For more information, explore FourTeck’s network and security products, review available technology services, or send the project requirement.

UAE availability and support guidance

Contact FourTeck to confirm current UAE availability for the Ubiquiti USW-Pro-XG-48. Supply may depend on regional version, quantity, vendor lead time and the accessories included in the requested bill of materials. Delivery and project coordination can be discussed after the exact requirement is confirmed. Installation and configuration scope should be included in the quotation when required.

For projects in Dubai, Abu Dhabi, Sharjah and Ajman, share the deployment address, rack location, required quantity, target date and whether the request includes optics, cables, UPS or RPS planning, configuration and migration. FourTeck can then coordinate a more relevant commercial response without assuming stock, fixed delivery dates or a standard installation scope.

GCC Availability

FourTeck can assist organisations planning USW-Pro-XG-48 deployments across GCC markets by reviewing the exact model, port requirements, uplink media, quantity and project scope before quotation. Requirements in the United Arab Emirates, Saudi Arabia, Kuwait, Qatar, Bahrain and Oman may involve different regional versions, delivery routes, lead times and service arrangements. Buyers should provide the destination country, requested quantity, preferred schedule, rack environment and whether configuration or installation coordination is required.

Product availability, shipment timing, service visits and accessory selection can vary by country and by the specific bill of materials. SFP28 optics, DACs, power accessories and support expectations should be confirmed rather than assumed. FourTeck can help align the switch request with the intended topology and can coordinate a quotation for hardware and clearly defined services. For Kuwait-related enquiries, customers may also review FourTeck Kuwait technology assistance.

Africa Availability

Organisations planning high-speed UniFi switching in Africa can contact FourTeck for requirement review, model confirmation, accessory planning and regional quotation coordination. The USW-Pro-XG-48 may be relevant to data-intensive offices, technology facilities and private infrastructure projects, but the complete design should account for destination, quantity, regional power arrangements, rack conditions, optics, fibre standards and local installation resources. Buyers should share the exact country, port schedule, preferred deployment date and any configuration or support expectations.

Availability and fulfilment may depend on vendor lead time, shipping arrangements, regional version and project conditions. FourTeck does not assume local inventory or guaranteed delivery. The team can help clarify the bill of materials and coordinate hardware, accessories and defined services for suitable projects. Regional enquiries can also be directed through FourTeck Africa, FourTeck Kenya or FourTeck Uganda according to the project location.

Related products and services to consider

USW-Pro-XG-48-PoE

Consider the PoE variant only when powered endpoints and its different port and power design match the requirement. Confirm the exact model rather than treating it as equivalent.

UniFi aggregation switching

A suitable aggregation switch may be needed when several access switches require 25G or 10G uplinks. Port type and topology should be reviewed together.

SFP28 optics and DACs

Select media by speed, distance, fibre type and peer compatibility. Accessories should appear as separate line items in the bill of materials.

Rack installation service

Installation scope may include mounting, cable management, labelling, power checks and physical handover, subject to site readiness and agreed responsibilities.

UniFi configuration support

Configuration may cover adoption, VLANs, trunks, link aggregation, access control and test plans according to the approved network design.

Why businesses contact FourTeck

High-speed switching purchases often fail at the details rather than the headline specification. A buyer may choose the correct switch but omit the right optics, underestimate rack depth, overlook the non-PoE design or assume existing cabling will negotiate at 10G. FourTeck helps customers review these practical dependencies before the order is finalised.

Assistance can include model clarification, port and uplink sizing, bill-of-material guidance, compatibility review, quotation coordination, installation planning, configuration scope and migration preparation. The objective is to make the commercial request specific enough that hardware and service responsibilities are clear. Learn more about FourTeck or discuss the requirement through the FourTeck UAE contact channel.

Frequently asked questions

Is the USW-Pro-XG-48 a PoE switch?

No. The USW-Pro-XG-48 is the non-PoE model. Buyers needing switch-powered access points, cameras or phones should evaluate a suitable PoE model and confirm its exact specifications.

How many 10G ports does it provide?

It provides 32 RJ45 ports supporting up to 10 GbE. These ports are multi-rate and also support 5G, 2.5G, 1G, 100M and 10M negotiation with compatible devices.

What are the remaining RJ45 ports?

The remaining 16 RJ45 ports support up to 2.5 GbE and can negotiate at 2.5G, 1G, 100M and 10M.

Does the switch support 25G uplinks?

Yes. It has four SFP28 interfaces supporting 25G, 10G and 1G. Suitable optics or direct-attach cables are required and should be matched to the peer equipment.

Can it perform Layer 3 functions?

Yes. Confirmed functions include DHCP server for local networks, DHCP relay, inter-VLAN routing and static routing within the supported UniFi environment.

Which UniFi Network version is required?

Ubiquiti specifies UniFi Network version 9.0.114 or later. The controller should be updated and backed up according to the organisation’s change process.

Are SFP28 modules included?

Do not assume that optics, DACs or fibre patch leads are included. The quotation should list the required media separately and identify the speed, distance and connector type.

Can FourTeck assist with installation and configuration?

Installation and configuration assistance can be discussed. The scope may include rack mounting, adoption, VLANs, trunks, link aggregation, migration and testing, depending on site readiness and the approved quotation.

How do I confirm Dubai availability?

Send FourTeck the exact model, quantity, required accessories, destination and target date. Availability and lead time may vary by regional version, quantity and vendor supply.

What information is needed for an accurate quote?

Provide the required quantity, endpoint speed and count, uplink design, optics or DAC needs, rack location, power plan, delivery destination and any installation, configuration or migration scope.

Plan the USW-Pro-XG-48 around your real traffic needs

Share the device count, target link speeds, uplink topology, rack location and service scope. FourTeck can help confirm the model, accessories and quotation for a Dubai or UAE deployment.

Discuss Your Requirement


Ask for Product Sizing

Reviews

There are no reviews yet.

Be the first to review “Ubiquiti Pro XG 48 USW-Pro-XG-48 Dubai”

Your email address will not be published. Required fields are marked *

Scroll to Top
Powered by Joinchat