Single-fibre Gigabit optical connectivity
MikroTik S-3553LC20D in Dubai, UAE
A matched pair of 1.25G single-mode SFP transceivers for point-to-point fibre links of up to 20 km over one LC UPC terminated fibre strand.
What buyers should confirm
Two compatible 1.25G SFP endpoints
Single-mode fibre with LC UPC connectors
One S-35LC20D at one end and one S-53LC20D at the other
Route distance, loss budget and installation conditions
Direct answer for buyers
The MikroTik S-3553LC20D is a two-module BiDi SFP kit for creating a 1.25G point-to-point optical connection over one strand of single-mode fibre. It is mainly used when two network devices need to be linked across a building, campus, warehouse, roadside cabinet, service-provider route or remote facility without using two fibre cores. Organisations should consider it when both endpoints provide compatible SFP cages and the planned route uses LC UPC single-mode fibre. Before ordering, confirm the exact endpoint models, route length, connector type, available fibre strand, expected optical loss, environmental conditions and whether diagnostics are required. Compatibility and final performance depend on the host devices and the installed fibre path.
What the kit does
The S-3553LC20D converts electrical Ethernet signalling from an SFP-equipped router, switch or media platform into an optical signal that can travel over single-mode fibre. Unlike a conventional duplex optical module that normally uses separate transmit and receive fibres, this pair uses two different wavelengths on one strand. The S-35LC20D transmits at 1310 nm and receives at 1550 nm, while the S-53LC20D performs the opposite task. Because the wavelength directions are complementary, the modules must be used as a pair with the correct module at each endpoint.
This approach can be valuable where only one fibre core is available, where an existing cable route has limited spare capacity, or where a business wants to preserve the second fibre strand for another service or future use. The module pair does not create routing, switching or security functions by itself. It is an optical interface component, so the host equipment remains responsible for network forwarding, configuration, monitoring and any access-control policy.
Who it suits
The product may suit IT teams, network contractors, managed service providers, system integrators and procurement teams planning straightforward Gigabit-class fibre connections between compatible equipment. Typical environments include offices with separate communications rooms, multi-building business sites, warehouses, hospitality properties, education campuses, industrial facilities, security-system networks and service-provider access links.
It is not the right choice when the required throughput exceeds 1.25G, when the installed fibre is multimode, when duplex LC cabling must be used with standard same-wavelength modules, or when either endpoint lacks a suitable SFP cage. Buyers planning shorter links should still assess optical power levels and the complete loss budget rather than assuming that every short patch is automatically appropriate. FourTeck can help review the endpoint models and link design before a quotation is finalised.
Business challenges this module pair can address
Limited spare fibre cores
A single-strand BiDi design can help an organisation establish a bidirectional link where only one usable single-mode fibre core is available. This may reduce the need to immediately install another cable, provided the existing route and connectors meet the optical requirements.
Long copper distance limitations
Ethernet over copper is distance-limited. A suitable optical link can connect buildings or network cabinets that are too far apart for ordinary twisted-pair cabling, while also avoiding an electrical path between the two endpoints.
Need for basic optical visibility
Digital diagnostic monitoring can expose operating information such as optical levels and temperature when the host platform supports reading those values. This can assist commissioning and troubleshooting, although DDM does not replace proper testing and documentation.
Capability overview
Product-fit matrix
| Requirement | Suitable when | Confirm before ordering |
|---|---|---|
| Use one fibre strand | The route has a spare single-mode core with LC UPC termination | End-to-end continuity, connector condition and patch-panel mapping |
| Gigabit-class connection | Both hosts support 1.25G SFP operation | Supported port speed and vendor compatibility policy |
| Long-distance building link | The calculated optical loss remains within the supported budget | Cable length, splices, connectors, splitters and measured attenuation |
| Operational diagnostics | The host can read DDM information from the module | Monitoring support, thresholds and network-management workflow |
Verified technical information
| Brand | MikroTik |
|---|---|
| Product code | S-3553LC20D |
| Kit contents | One S-35LC20D and one S-53LC20D transceiver |
| Format | SFP |
| Data rate | 1.25G |
| Fibre mode | Single mode |
| Connector | Single LC UPC |
| Maximum stated distance | 20 km, subject to the complete optical link budget |
| Wavelengths | 1310 nm / 1550 nm complementary operation |
| Digital diagnostics | DDM supported; visibility depends on host equipment |
| Tested ambient temperature | -40°C to +70°C |
| Suggested manufacturer price reference | US$79.00; not a confirmed UAE selling price |
| UAE availability | Contact FourTeck for current options, quantity and lead-time guidance |
Compatibility and dependency notice
The S-3553LC20D should be treated as a matched optical pair. Installing two identical halves at opposite ends will not create the intended link because the transmit and receive wavelengths must complement each other. The product is designed for single-mode fibre and a single LC UPC connection. Buyers should not assume compatibility based only on the physical SFP shape. The host device must support 1.25G SFP transceivers, and some equipment vendors apply their own coding, support or warranty policies for third-party optics. MikroTik identifies a range of tested MikroTik devices and states that the modules are also compatible with non-MikroTik SFP devices, but the exact endpoint models should still be checked before procurement.
The 20 km figure is a maximum stated reach, not a promise that every 20 km route will work without engineering review. Fibre attenuation, connector loss, splice loss, dirty end faces, patch-panel quality, bends and any passive components all affect the optical budget. Very short laboratory links may also need an optical power assessment. For a business deployment, arrange proper cleaning, inspection, measurement and documentation rather than relying only on link LEDs.
Purchase and deployment journey
Confirm the endpoints
Provide the exact router, switch, media converter or platform model at each end. Confirm SFP support, intended speed, operating software and any vendor restrictions on optical modules.
Review the fibre path
Record route distance, fibre type, number of splices, patch panels, connector style and measured loss. Confirm that one continuous single-mode strand is available end to end.
Prepare the bill of materials
Include the module pair, suitable LC UPC patch leads, cleaning tools, labelling materials, any required adapters and installation or testing services.
Install and validate
Place the complementary modules at opposite ends, clean all interfaces, configure the host ports correctly and check link state, errors, traffic flow and available DDM readings.
Using one fibre strand efficiently
The most important operational characteristic of this kit is its bidirectional wavelength design. A conventional optical link often consumes two fibres: one for transmit traffic and another for receive traffic. The S-3553LC20D pair sends both directions across one strand by assigning a different wavelength to each direction. For organisations with an existing single-mode backbone, this can make better use of limited fibre resources and may preserve other cores for redundancy, additional tenants, surveillance traffic or future expansion.
That efficiency is particularly relevant in older buildings, leased facilities or external routes where pulling a new cable is disruptive or costly. It also introduces a clear installation discipline: each module must be labelled and placed at the correct endpoint. Network diagrams should identify which side uses S-35LC20D and which side uses S-53LC20D. Spare management should also preserve matched pairs so that technicians do not accidentally replace one side with the wrong wavelength.
A single fibre design does not automatically provide resilience. If business continuity is important, consider whether a second independent path, alternate cable route, redundant switch, ring architecture or backup wireless link is required. FourTeck can help discuss the role of this optical pair within a wider network design, but the final resilience strategy depends on the site layout, service priorities and budget.
Monitoring and troubleshooting with DDM
Digital diagnostic monitoring can provide useful operational data from an optical transceiver when the host device supports it. Depending on the platform, administrators may be able to review received optical power, transmitted power, module temperature, voltage and laser bias information. These readings can help distinguish between a fibre-path problem, a marginal optical level and a host configuration issue.
DDM should be used as one part of a structured troubleshooting process. An engineer should first verify that the complementary modules are installed at the correct ends, that the host ports are enabled and configured for the expected speed, and that the fibre path is continuous. Connector cleaning is essential because microscopic contamination can create substantial loss. If a link remains down or unstable, use suitable optical test equipment to measure the route rather than assuming the module is faulty.
For ongoing operations, document normal baseline readings after installation. A later change in receive power may indicate connector degradation, fibre damage, additional patching or a developing bend. Alert thresholds and monitoring capabilities vary by platform, so buyers who require centralised optical monitoring should confirm what their routers or switches can expose through RouterOS, SNMP or another management interface.
Host compatibility and lifecycle planning
Physical fit is only the first compatibility requirement. SFP cages may support different speed classes, coding expectations and software behaviours. MikroTik lists the S-3553LC20D as tested with selected MikroTik devices and also states compatibility with non-MikroTik SFP devices. Even so, procurement teams should confirm the current documentation for both endpoint products, especially where one side is from another manufacturer or where the equipment is operating under a restrictive vendor-support policy.
The endpoint model should also match the intended service life. Installing a new optical link between devices nearing replacement may not be the most efficient approach if a higher-speed backbone is planned. The S-3553LC20D is a 1.25G kit; businesses expecting multi-gigabit growth should compare the cost of deploying this pair now with the value of selecting a higher-speed platform and compatible optics. A Gigabit link can remain entirely appropriate for management networks, branch connections, voice systems, surveillance segments or moderate application traffic, but capacity should be based on measured and forecast use.
For spares, keep a complete pair rather than isolated modules. Record serial numbers, endpoint locations and wavelength direction. If the link is part of a critical service, consider maintaining tested spare patch leads and a documented replacement procedure. Warranty terms, replacement processes and availability should be confirmed at the time of quotation because they may vary by source, region and current vendor policy.
Suitable business environments
Campus and multi-building links
Connect administrative offices, classrooms, workshops or remote communications rooms where single-mode fibre already runs between buildings.
Warehouses and industrial sites
Extend network access to distant cabinets, loading areas or production zones while avoiding copper distance constraints and direct electrical continuity.
Service-provider access
Create a straightforward 1.25G optical handoff or point-to-point segment where the devices, fibre type and operational policies support the pair.
Surveillance and security networks
Link remote camera aggregation switches or security buildings, provided the total bandwidth and redundancy design meet operational requirements.
Integration and operational considerations
Plan the optical module as part of a complete link, not as an isolated purchase. The required bill of materials may include single-mode fibre patch leads, LC UPC adapters, patch-panel ports, cleaning tools, labels, cable-management accessories and test services. Verify that APC connectors are not being mixed with UPC connectors. Although both may use an LC body, the end-face geometry differs and incorrect mating can create significant loss or damage.
Port configuration should be reviewed on both hosts. Some devices negotiate speed automatically, while others may require explicit settings. Confirm whether auto-negotiation, forced speed, flow control or bridge configuration is appropriate. The module pair only provides physical connectivity; VLAN design, IP addressing, routing, spanning tree, link aggregation and security policies are configured on the connected devices.
Environmental planning matters for outdoor cabinets and industrial rooms. The official specification lists a tested ambient range from -40°C to +70°C, but the complete host device, power supply, enclosure and ventilation arrangement must also be suitable. High cabinet temperatures, dust, moisture and poor cable management can affect the wider deployment even when the optical module itself is rated for a broad temperature range.
Buyer questions to resolve before ordering
Share manufacturer, model and software version so SFP support can be reviewed.
Confirm cable type, patch cords, connectors, splices and any passive components.
Distance alone is not enough; the full optical loss budget should be considered.
A single strand is efficient but remains one physical path unless a backup is designed.
Include cleaning, labelling, commissioning and documentation in the requested scope.
Review current utilisation and future application, camera or user demand.
Procurement checklist
☐ Exact product code: S-3553LC20D
☐ Required number of matched pairs
☐ Endpoint device model at side A
☐ Endpoint device model at side B
☐ Confirmed 1.25G SFP support
☐ Single-mode fibre route
☐ LC UPC connector confirmation
☐ Route length and measured attenuation
☐ Patch leads and adapters required
☐ Installation and testing scope
☐ Redundancy or backup-path requirement
☐ Monitoring and DDM requirement
☐ Delivery destination and target schedule
☐ Warranty and replacement guidance
How FourTeck can assist
FourTeck can help business buyers clarify whether the MikroTik S-3553LC20D matches the intended optical link. The review can start with the endpoint models, site locations, fibre type, connector format, route distance, quantity and required project date. This information allows the quotation discussion to include the correct module pair and any practical accessories or services that should be considered.
Where required, FourTeck can coordinate a broader requirement review covering compatible routers or switches, patch leads, configuration scope, installation planning and commissioning expectations. Product supply, site work and configuration are separate scope items unless specifically included in the quotation. Buyers can explore related network and security products, review available technology services, or send the requirement through the FourTeck contact page.
UAE availability and support guidance
Contact FourTeck to confirm current UAE availability for the MikroTik S-3553LC20D. Availability may depend on quantity, sourcing route and vendor lead time. Delivery and project coordination can be discussed after the exact requirement is confirmed. Buyers should provide the destination, number of module pairs, endpoint equipment, desired schedule and whether patch leads, installation, configuration or testing are required.
For projects across Dubai, Abu Dhabi, Sharjah and Ajman, FourTeck can coordinate requirement review and quotation planning from one consolidated brief. The same product may be used in very different environments, so the quotation should reflect the real link design rather than only the module code. Installation and configuration scope should be included in the quotation when required. Product warranty guidance and any return conditions should also be confirmed before the purchase order is issued.
GCC Availability
FourTeck can assist organisations planning MikroTik optical links across GCC markets by reviewing the intended endpoints, fibre route, module quantity and deployment scope before quotation. This can be relevant for businesses operating across the United Arab Emirates, Saudi Arabia, Kuwait, Qatar, Bahrain and Oman, especially where network standards need to be kept consistent across branches or project sites. Product availability, delivery schedules, service visits and vendor lead times can vary by country, model, quantity and requirement. Buyers should share the destination country, exact product code, required number of pairs, endpoint device models, deployment location and expected timeline. Where installation, testing or configuration is needed, that scope should be discussed separately and included in the commercial proposal. No local inventory, customs outcome or fixed deployment date should be assumed until the requirement and destination have been reviewed. For Kuwait-focused coordination, buyers may also visit FourTeck Kuwait.
Africa Availability
FourTeck can support organisations evaluating the MikroTik S-3553LC20D for projects in Africa by helping them define the exact optical requirement, suitable accessories, endpoint compatibility and procurement scope. This may include projects in East Africa, West Africa, Southern Africa or Central Africa, with specific support pathways available through FourTeck Kenya, FourTeck Uganda and the wider FourTeck Africa network. Availability and fulfilment may depend on the destination, product quantity, fibre accessories, shipping arrangements, vendor lead time and local project conditions. Buyers should share the destination country, exact number of module pairs, endpoint models, route details, preferred deployment schedule and any installation or support expectations. Local inventory, immediate shipment, customs clearance and country-wide onsite coverage should not be assumed unless they are specifically confirmed in the quotation.
Related options and services
Compatible MikroTik routers and switches
Review current MikroTik platforms with suitable SFP cages and the capacity required for the wider network design.
Single-mode LC patch leads
Select the correct UPC connector style, cable length and fibre grade for each endpoint and patch panel.
Higher-speed optical alternatives
Where more than Gigabit capacity is required, compare suitable SFP+, SFP28 or other optical options rather than forcing this kit into an undersized role.
Installation and fibre testing
Include connector inspection, cleaning, loss measurement, labelling and commissioning where the project requires documented handover.
Why businesses contact FourTeck
Businesses commonly contact FourTeck when they need more than a part number. The practical questions often concern whether the modules fit the selected host devices, whether the existing fibre route is suitable, which patch leads are required, how many pairs should be held as spares and whether installation or testing should be included. FourTeck can help organise those questions into a clearer bill of materials and quotation request.
This approach can reduce avoidable ordering errors such as mixing connector types, overlooking the need for complementary wavelengths, purchasing optics for an unsupported port speed or omitting patch accessories. It also helps procurement teams separate confirmed product facts from configuration-dependent assumptions. For company information, visit about FourTeck or send a technical and commercial brief through the contact page.
Frequently asked questions
Is the S-3553LC20D one module or a pair?
It is a pair consisting of one S-35LC20D and one S-53LC20D. The modules use complementary transmit and receive wavelengths and are intended for opposite ends of the same link.
Can it use one fibre strand?
Yes. The pair is designed for bidirectional communication over one single-mode fibre strand through 1310 nm and 1550 nm wavelength pairing.
What connector does it use?
The official specification lists a single LC UPC connector. Confirm that the complete route and patch leads use the correct connector type.
Will it work over multimode fibre?
The product is specified for single-mode fibre. A multimode route should not be treated as suitable without a different optical design and compatible modules.
Is 20 km guaranteed on every link?
No. Twenty kilometres is the stated maximum reach. Actual operation depends on total fibre loss, connector quality, splices, patching and the host equipment.
Does it support optical diagnostics?
Yes, the modules support DDM. The connected router or switch must also support reading and presenting the diagnostic values.
Can it be used with non-MikroTik equipment?
MikroTik states that the units are compatible with non-MikroTik SFP devices, but buyers should still check the exact host model, speed support and vendor policy before ordering.
Are patch cables included?
The official product is described as a two-module kit. Required patch leads and other accessories should be confirmed and added to the quotation where needed.
What details are needed for a quotation?
Provide the required quantity, endpoint device models, fibre type, route distance, connector information, destination and whether installation, testing or configuration support is required.
How can I confirm UAE availability?
Contact FourTeck with the product code and quantity. Availability, lead time, delivery coordination and warranty guidance will be confirmed against the current requirement.
Confirm the module pair before you order
Send FourTeck the endpoint models, fibre details, link distance, quantity and destination for compatibility review, UAE availability guidance and a commercial quotation.